Solavel Docs
English

Add a device

Last updated

This page takes you from "I have a terminal on the wall" to "SolaHR reads it": finding the device, choosing it in the model catalog, gathering the IP address, port and Comm Key from the device's own menu, testing the connection and understanding the status you get back. The click-by-click screen reference is in Attendance devices; this page adds the knowledge you need around it.

Before you begin, the connector should be installed and showing Online, unless you plan to use push or file import.

#The short version

  1. Time & Attendance → Attendance Devices → Add device.
  2. Name it, choose its attendance location and the Device clock timezone (for example Asia/Amman).
  3. Choose the Connection type, the Connector, and enter the Device IP address, Port and Comm key (empty means 0).
  4. Test connection. A good answer shows model, firmware, users and records on the device and its clock.
  5. Map the users, then Save and start sync.

You can leave half-way: an unfinished device shows Setup incomplete with Resume setup.

#Discovery: let the connector find the device

On the connector PC open the connector page (http://127.0.0.1:8790) and press Find devices. It does a read-only search of the local network and does not change anything. In SolaHR the results show under Found by your connector with their address and port; one click fills in the address. Devices that ask for a Comm key are marked "asks to sign in (Comm Key, often 0)".

Discovery only sees devices on the same network segment as the PC and only protocols the connector knows. If your terminal is not found, it may be on another VLAN, or it may be a type that is not read directly. Type the address yourself.

#The model catalog

Under Your device you can search the catalog by brand or model. At this release it has 147 models from ZKTeco, Hikvision, Suprema, Anviz and EBKN. Choosing one shows:

Shown Meaning
Tested on a real device Connected for real, with the firmware named. Today only the ZKTeco iFace702.
Expected to work · same protocol family Documented to use the same protocol as a model that works; not tried by us.
Unknown: not tested In the catalog, but there is no evidence either way.
Recommended settings A button, Apply recommended settings, fills in port, transport and encoding.
Where to find settings on this device The menu path (summarised below).
Known issues and Next steps For example, ZKTeco firmware Ver 6.60 asks to sign in even with Comm Key 0; connector 0.1.5 and later handle it.

The model is optional. If the best connection type for the model differs from the one you picked, SolaHR offers Switch to .... The full list, with the official manual and support links, is on Supported devices. A device that is not in the catalog can still work if it uses one of the same protocols; try Test connection.

#Find the IP address, port and Comm Key on the device

Every manufacturer words the menus a little differently, and menus change with model and firmware. Use these paths as a guide and confirm in your device's own manual (links in Supported devices).

#ZKTeco (direct, port 4370)

On most ZKTeco terminals, press Menu and:

You need Where on the device
IP address, subnet mask, gateway, DHCP Menu → Comm. → Ethernet
Port TCP COMM. Port in the same screen. The factory value is 4370; leave it unless you changed it.
Comm Key Menu → Comm. → PC Connection → Comm Key. A number of 1 to 6 digits; 0 means no key (the factory value).
Device ID / machine number Same PC Connection screen. Leave SolaHR's Machine number at 1 unless your device uses another.
ADMS server (for push, instead of the connector) Menu → Comm. → Cloud Server Setting: the server address (or a domain name, if the domain option is on) and the server port.

A factory-fresh ZKTeco terminal is documented to start at IP 192.168.1.201 with mask 255.255.255.0, so the PC and the terminal must be on the same segment, or you change the device's address first. The menu names above come from ZKTeco's own current manuals (for example the SpeedFace-V3L user manual); older terminals such as the iClock series have similar menus. Transport: leave Auto (TCP first, UDP only if TCP fails). Arabic names look garbled: keep UTF-8, then try Windows-1256 (cp1256), then GBK.

#Hikvision (ISAPI, web port 80)

Hikvision terminals are configured mostly through their built-in web page.

You need Where
Find the device on the network Hikvision's SADP tool (in HiTools) lists Hikvision devices on the local network, activates new ones and can change their IP. Hikvision says SADP stops receiving updates from April 2026 and points to its newer HiTools Delivery.
IP address Device web page → Configuration → Network → Basic Settings → TCP/IP
A login for SolaHR Web page → Configuration → System → User Management. Create a separate user for SolaHR; do not use admin.
Port 80 (HTTP), unless changed in the device's network settings

A new Hikvision device must be activated (you set its admin password) before it can be used. Hikvision documents factory addresses in its manuals; confirm yours there rather than guessing.

#Suprema (through a BioStar 2 server)

SolaHR does not talk to Suprema terminals directly. It reads events from your BioStar 2 server.

You need Where
Server address The address of the BioStar 2 web page, usually https://<server>:443
A login In BioStar 2, create a read-only operator; do not use the main administrator
Event types BioStar 2 labels each event with a code; if you import too much, set the allowed event codes in the device settings in SolaHR

Terminal IP addresses and server settings are set in BioStar 2 itself; see the BioStar 2 Administrator Guide.

#Anviz (direct, TCP 5010, or CrossChex Cloud)

You need Where
IP address and port Device menu → Communication / Network (some models: the device's web page). The default port is 5010.
TCP mode Set it to Server, so the connector PC can connect to the device. (Client mode makes the device connect out to a PC, for devices on another network.)
Device ID In the same communication menu, if you use one
Port and ID must match The port in SolaHR must equal the port set on the device

For CrossChex Cloud, you need an Anviz cloud account with developer access (API key and secret); there is nothing to set on the connector PC. SolaHR also asks how the cloud's checktime should be read (UTC or local), because Anviz does not state it clearly: choose according to what you see in CrossChex Cloud.

#EBKN / Secureeye (push only)

There is no direct connection. In the device's server/cloud settings enter the push address shown on the device page in SolaHR.

#Any other terminal

Use File import (export from the device) or, if the terminal or its software can send punches to a web address, the generic push route (SolaHR shows a one-time address and token).

#Test connection

Press Test connection. SolaHR asks the connector to contact the device; it usually takes a few seconds. A good answer shows Model, Firmware, Users on device, Records on device and the Device clock. If the clock is more than two minutes off you get a warning, because punch times follow the device clock. You may Skip for now.

#What the status means

You see What it means What to do
Reachable (green), with model and counts The device answered and the key was accepted. Continue to mapping.
Reachable · Comm Key rejected The device is there but the key is wrong. Enter the Comm Key from Menu → Comm. → PC Connection. A device with no key is key 0.
Reachable · device busy The device is occupied (often someone is enrolling or the device is syncing). Wait a minute and test again.
Device unreachable / "did not answer in time" Nothing answered at that address and port. Power, cable, address, port, same network, firewall. See Troubleshooting.
"The connector did not pick up the request" The connector PC is off, asleep or offline. Switch it on. Waiting punches are sent afterwards.
Setup required This connection type needs the manufacturer's software on the PC and it is not ready. This is a status, not a fault of the terminal. Follow Vendor SDK setup, or switch to the built-in direct connection.
"Serial mismatch" The device at that address is not the one registered. Check the IP address; two devices may have swapped addresses.
"Connector was revoked" / "needs re-pairing" The connector lost its pairing. Pair again on the Connectors tab.
Setup incomplete You left the guided steps before the end. Resume setup.
Offline / "Connector ... is offline" (on the card) The connector PC is off or has no network. Switch it on; waiting punches are sent later.
"Device pushes to SolaHR - last contact ..." (push devices) When SolaHR last heard from the device. If it is old, check the device's server setting and network.

#Push devices (ADMS and similar)

Instead of a connector, a terminal can push punches to SolaHR. You register the device in SolaHR first (SolaHR needs its serial number), then enter SolaHR's address in the terminal's cloud/ADMS setting (Menu → Comm. → Cloud Server Setting on ZKTeco). Push is simple but trusts the device's serial number, so keep the allowed network as narrow as possible and review the punches. Many ADMS terminals speak plain HTTP only; your administrator may need to allow that on the web server, which the Installation readiness panel on the devices page checks.

#Next